ASTM C773 PDF

Purchase your copy of ASTM C – 88() as a PDF download or hard copy directly from the official BSI Shop. All BSI British Standards. Designation: C − 88 (Reapproved ) Standard Test Method for For referenced ASTM standards, visit the ASTM website, , or. Find the most up-to-date version of ASTM C at Engineering

Author: Maulabar Moogudal
Country: Burkina Faso
Language: English (Spanish)
Genre: Career
Published (Last): 8 August 2013
Pages: 227
PDF File Size: 19.73 Mb
ePub File Size: 11.60 Mb
ISBN: 714-8-45056-646-3
Downloads: 92031
Price: Free* [*Free Regsitration Required]
Uploader: Kigat

Significance and Use 3. Originally published as C — 74 to replace C and C Enviado por Thamyres flag Denunciar. C 5 compressive strength of the specimen, psi or MPa; P 5 total load on the specimen at failure, lbf or N; and A 5 calculated area of the bearing surface of the specimen, in. This test is a measure of the potential load-bearing usefulness of a ceramic.

Current edition approved Sept. Precision aatm Bias 8. Suitable materials for cushion pads, selected in accordance with the compressive strength range of the material being tested, are shown in the following table: The compo- nents of variance for compressive strength results expressed as coefficients of variation were calculated as follows: C — 88 Reapproved Standard Test Method for Compressive Crushing Strength of Fired Whiteware Materials1 This standard is issued under the fixed designation C ; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision.

  GEOTOPER 1 PDF

Last previous edition C asstm 88 NOTE 1—It is desirable to include details of the origin of the specimen and subsequent treatment.

ASTM International – Laboratory Directory – University of Dayton Research Institute

Place an appropriate guard around the specimen to contain flying fragments at failure; eye protection should be used by the operator. A number in parentheses indicates the year of last reapproval. One operator in each laboratory tested ten specimens of each material. Discard any pieces exhibiting cracks or flaws visible to the unaided eye. The spherical surfaces shall be well lubricated, and the center of curvature shall lie on the lower face of the platen.

ASTM C 773 – 88

New cushion pads shall be used for each specimen. A superscript epsilon e indicates an editorial change since the last revision or reapproval. Single-operator component Between-laboratory component 1. It is the responsibility of the user of this standard to establish appro- priate safety and health practices and determine the applica- bility qstm regulatory limitations prior to use.

  BITTERBLUE DI KRISTIN CASHORE PDF

ASTM C773 – 88(2016)

The ends of all specimens shall be ground or lapped to yield plane and parallel faces. They may be formed and matured for the purpose of compression testing, or they may be cut from matured whitew- are by sawing or coredrilling.

If the contact block is cracked during testing, it shall be replaced. These faces shall be perpendicular. Ideally, ceramics should be stressed this way in use.